Output VoltageTD | Output Current Min. | Output Current Max. | Regulation Load | Regulation Line | Output Ripple & Noise Max.[P-P] |
+5V | 0.5 | 25.0 | ±5% | ±50mV | 50mV |
+12V | 2.0 | 48.0 | ±5% | ±120mV | 120mV |
-12V | 0.2 | 0.8 | ±10% | ±120mV | 120mV |
+3.3V | 0.5 | 25.0 | ±5% | ±50mV | 50mV |
+5VSB | 0.1 | 3.5 | ±5% | ±50mV | 50mV |
* TEMPERATURE RANGE: OPERATING: 0 ℃ ~ 40 ℃, STORAGE: -20 ℃ ~ 80 ℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: >80% TYPICAL AT 115V, 20~**** MAX LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms
* OVER POWER PROTECTION: 110~180%
* OVER VOLTAGE PROTECTION: +5V: 5.9~6.7V, +3.3V: 3.9~4.3V, +12V: 13~15V
* OVER CURRENT PROTECTION: +3.3V: 27.5~37.5A, +5V: 27.5~37.5A, +12V: 52.8~76.8A
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V
* SAFETY: TO MEET UL, CUL, TUV, CCC
* REMOTE ON/OFF CONTROL
* WARNING METHOD: AUDIO ALARM, FAULT LED, TTL
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.